Premier Flanged Blow-Out Preventer 500F

    Flanged BOP with integral tee, patented Snap-Loc™ seal, and inter-locking ram. Available in single or dual ram configuration with manual or hydraulic actuation. LP or studded side outlets on dual ram. 5K top × bottom flange standard. 100% factory tested, NACE standard.

    • PREMIER BOP

    Quick Specifications

    WORKING PRESSURE                                                                               5,000 PSI Max.
    BTM FLANGE                                                                                  2-9/16"/5M or 7/10M
    TOP FLANGE                                                             5K (10M BTM option — dual ram)
    ACTUATION                                                                                       Manual or Hydraulic
    RAM CONFIGURATION                                                                      Single or 
    Dual Ram
    RAM SIZES                                                                                               Blind, 1-¼", 1-½"
    SIDE OUTLETS (SINGLE)                                               3-1/8" flange with integral tee
    SIDE OUTLETS (DUAL)                                                                               LP or Studded
    NACE                                                                                                   MR-01-75 Standard
    FACTORY TESTED                                                                        100% Pressure Tested
    FLANGE ALTERNATIVES                                                            Available upon request

    Key Features

    WHY THE MODEL 500F

    Flanged Connection

    Flanged body eliminates the need for threaded wellhead connections at the BOP — providing a more positive, leak-resistant interface for high-cycle pressure applications.

    Manual or Hydraulic Actuation

    The 500F is available with manual hand wheel or hydraulic cylinder actuation — the same model, the same part number, with the actuation method specified at time of order.

    Integral Tee Included

    Both single and dual ram models include the integral tee — combining the BOP body and flow cross into one unit, reducing overall wellhead height and connection count.

     

    Single or Dual Ram

    Single ram model includes 3-1/8" flange with integral tee. Dual ram model adds LP or studded side outlets and an optional 10M BTM flange. Specify at time of order.

    Snap-Loc™ + Inter-Locking Ram

    Same patented Snap-Loc™ seal and new inter-locking ram design used across the Premier BOP line. Positive closure integrity under sustained 5000 PSI service.

    100% Factory Tested + NACE

    Every 500F is pressure tested at the factory. NACE MR-01-75 standard — no additional modification required for sour service approval.

    Full Specifications

    WORKING PRESSURE                                                                               5,000 PSI Max.
    BTM FLANGE                                                                                  2-9/16"/5M or 7/10M
    TOP FLANGE                                                             5K (10M BTM option — dual ram)
    ACTUATION                                                                                       Manual or Hydraulic
    RAM CONFIGURATION                                                                      Single or 
    Dual Ram
    RAM SIZES                                                                                               Blind, 1-¼", 1-½"
    SIDE OUTLETS (SINGLE)                                               3-1/8" flange with integral tee
    SIDE OUTLETS (DUAL)                                                                               LP or Studded
    NACE                                                                                                   MR-01-75 Standard
    FACTORY TESTED                                                                        100% Pressure Tested
    FLANGE ALTERNATIVES                                                            Available upon request

    Product Notes

    • Flanged body for wellhead connection — no threaded connections at BOP
    • Integral tee included — combines BOP and flow cross in one body
    • Snap-Loc™ patented seal design for positive closure
    • NEW inter-locking ram prevents walkout
    • Manual or hydraulic actuation available on same model
    • Single or dual ram configurations available
    • LP or studded side outlets on dual ram model
    • 5K top × bottom flange standard (10M BTM option on dual ram)
    • 100% factory pressure tested
    • NACE MR-01-75 standard
    • Alternative flange sizes available upon request

    Compatible Accessories

    WSI accessories and complementary products for the 500F.

    Step Up to 10,000 PSI

    1000F
    Same flanged format, integral tee, and Snap-Loc™ seal — rated to 10,000 PSI for the most demanding wellhead applications. Studded outlets only.

    Threaded Version — Same PSI

    500T
    Prefer threaded connections? The 500T provides 5000 PSI Premier BOP performance with EUE and LP threaded connections.

    Threaded — 3000 PSI

    300T
    For lower-pressure applications, the 300T provides Premier BOP performance at 3000 PSI with threaded connections.

    Related Products

    Other WSI products in the same category that may better suit your application, pressure requirements, or well conditions.

    Premier Flanged 1000F

    Premier Flanged 1000F

    Studded only
    10,000 PSI
    Premier Threaded 500T

    Premier Threaded 500T

    EUE/LP Connections
    5000 PSI
    Premier Threaded 300T

    Premier Threaded 300T

    3000 PSI

    READY TO ORDER THE 500F?

    Available in single or dual ram. Manual or hydraulic actuation. BTM flange: 2-9/16"/5M or 7/10M. LP or studded side outlets on dual ram. Specify ram size and rubber compound. Alternative flange sizes available.

    upc global logo

    Contact us

    24285 Katy Fwy Suite 300

    Katy, TX 77494