Load Cell Replacement Installation Service

Sucker Rod Pump Load Cell Installation

Image

UPC Global will supply the company with specialized load cell installation service personnel.

Sucker Rod Pump Load Cell Installation

This procedure applies to all land operations where the load cell installation on mechanical pumping units must be carried out.

Deliverables

  • Report of the activity with its photographic record and load cell test report.
  • A dynamometric card with the Echometer Well Analyzer will be taken after the installation to validate installed permanent load cell peak loads and minimum loads reported by the POC.

Equipment, Materials & Tools

For the execution of Sucker Rod Pump (SRP) Load Cell Installation, each crew requires the following:
  • One Bucket Truck
  • Multimeter
  • Adjustable wrenches of different diameters
  • To hold rod string, two 3-point clamps (50,000 lbs) each
  • One 1-1/4 Impact wrench
  • Pipe wrenches of different diameters
  • Ladder
  • One torque wrench
  • Meter and tape measure
  • Hydraulic jack (Hydralift)

Equipment, Materials & ToolsPersonnel Provided for this Service:

  • Two Field Technicians with advanced knowledge in POC Genesis/SAM and Artificial Lift Systems.
© 2024 Unlimited Petroleum Consulting l UPC Global All Rights Reserved.

upc global logo

Contact us

24285 Katy Fwy Suite 300

Katy, TX 77494